Home
Products > Products comparison
 29/05/2008
Bluetooth® 3G / 3G+ GSM / GPRS
(900 / 1800 MHz)

GPS ISDN
(128 Kbits/s)
PSTN/LL
(2 wires)
Stack TCP/IP USB RS232 RS485 Inputs Outputs ana 4-20
Inputs
Power Supply
In communication
Consumption
Stand-by
Consumption
Operating
Temperatures
            3 1   5.5 @ 32 Vdc 105 mA @ 12 Vdc
GSM 900 MHz + GPS
5 mA @ 12 Vdc -20°C / +55°C
                      3.8 to 20 Vdc
external or via RS232
25 mA connected mode
60 mA in transmission
NC -30°C / +70°C
                      3.8 to 20 Vdc
external or via RS232
25 mA connected mode
60 mA in transmission
NC -30°C / +70°C
                      3.8 to 20 Vdc
external or via RS232
25 mA connected mode
60 mA in transmission
NC -30°C / +70°C
              UART         3.6 Vdc or 5 Vdc 210 mA @ 5 Vdce
GSM 850/900 MHz
15mA @ 5 Vdc -30°C / +70°C
     GSM             3 1   5.5 to 32 Vdc 105 mA @ 12 Vdc
GSM 850/900 MHz
5 mA @ 12 Vdc -20°C / +55°C
                      5.5 to 32 Vdc 105 mA @ 12 Vdc
GSM 850/900 MHz
5 mA @ 12 Vdc -20°C / +55°C
              3 1   5.5 to 32 Vdc 105 mA @ 12 Vdc
GSM 850/900 MHz
5 mA @ 12 Vdc -20°C / +55°C
                      5 to 32 Vdc 195 mA @ 12 Vdc
GSM 850/900 MHz
20 mA @ 12 Vdc -25°C / +60°C
                    Rechargeable battery
via USB
NC NC -30°C / +70°C
                    Rechargeable battery
via charger
Autonomy: 45 days
(1 position per day)
NC -30°C / +70°C
                    Rechargeable battery
via charger
Autonomy: 90 days
(1 position per day)
NC -30°C / +70°C
                      230 Vac < 10 VA NC -10°C / +55°C
                      4 to 28 Vdc < 18 mA < 9 mA -15°C / +60°C
          PSTN           6 to 30 Vdc 75 mA @ 12 Vdc NC 0°C / +50°C
                    6 to 30 Vdc 80 mA @ 12 Vdc NC 0°C / +50°C
              4

**
2

**


**
5 Vdc
or
7,5 to 48 Vdc
255 mA @ 5 Vdc
or
152 mA @ 12 Vdc
Stand-by mode
< 10 µA
-15°C / +60°C
                      5 Vdc NC NC 0°C / +55°C
          *   4

**
4

**
*

**
7,5 to 30 Vdc 200 mA @ 12 Vdc
GSM 900 MHz
75 mA @ 12 Vdc -10°C / +55°C
          *         GenSmi-AC : 230 Vac
or
GenSmi-DC : 6 to 32 Vdc
GenSmi-AC : 6 W
or
GenSmi-DC : 208 mA
@ 12 Vdc - GSM 900 MHz
GenSmi-AC : 3 W
or
GenSmi-DC : 11 mA
@ 12 Vdc - GSM 900 MHz
-20°C / +55°C
          *           5 Vdc NC NC -0°C / +55°C
"Embedded" range
"Case" range
"Rail-DIN" range
NC : Not communicated
* : Option (consult us)
** : Option extension board (8 inputs + 8 outputs + 4 ana 4-20 mA inputs) for GenIndus / Gen 44i.
back
 
Home - Contact - Plan du site - Legal notice -